DOB proposed six standard sidewalk shed designs. Comments closed September 24, and the rule page still lists the rule as proposed.

The proposal would let an engineer design a shed from one of six DOB packages. The engineer would still design for the site. Companion to our post on Get Sheds Down.

The Department of Buildings has proposed a rule that would let an engineer or architect design a sidewalk shed from one of six standard packages instead of from scratch. The proposal is new section 3307-03 of Title 1 of the Rules of the City of New York. DOB scheduled its public hearing for September 24, 2026, which was also the comment deadline. As of November 12 the NYC Rules page lists the rule as proposed, and we found no adopted version.

Where the rule comes from

DOB says Local Law 47 of 2025 "required the Department of Buildings ('the Department') to evaluate sidewalk shed designs to determine whether improvements over existing shed designs can be made to improve the pedestrian experience without diminishing the safety of the sidewalk shed." The same law amended Building Code section 3307.6.4 so that DOB may adopt rules that add to, delete or modify the requirements in sections 3307.6.4.1 through 3307.6.4.11 "as necessary to support the implementation of new sidewalk shed designs" (DOB proposed rule notice and text). The proposal is that rulemaking. It follows a 2025 design study run by DOB.

The six designs

The study produced six standardized designs, and the rule names all six: the Air Shed, Baseline Shed, Flex Shed, Rigid Shed, Speed Shed and Wide Baseline Shed. The proposed text links each one to a design package on DOB's website. A registered design professional "may utilize one of the six Standard Design Packages as the basis for the design of a sidewalk shed." Construction documents that incorporate material from a package must clearly identify which package is used.

What the packages replace in the Building Code

Under subdivision (d)(3), a shed built to a package would follow the package, not the Building Code text, on several points: the vertical member and beam requirements of items 2, 7 and 8 of section 3307.6.4.4, the decking requirements of items 1 through 4 of section 3307.6.4.5, the height requirements of section 3307.6.4.7 and the lighting requirements of section 3307.6.4.8. Where a package does not require a parapet, the shed would be exempt from the parapet rules of section 3307.6.4.6 and from the signage and artwork requirements of sections 3301.9.2 and 3307.11.

On loads, the text says that where the installation "otherwise conforms to the selected Standard Design Package, no further analysis of the Building Code Chapter 16 design loads incorporated into the Standard Design Package is required."

What stays with the engineer

The proposal does not turn a shed into an off-the-shelf product. Subdivision (d) says "A site-specific design must be prepared by a registered design professional for each installation," and that the professional must verify that existing site conditions, "including foundations, shims, sidewalk vaults, utility structures and similar features," are compatible with the design. Subdivision (c)(5) says nothing in the section relieves the professional of responsibility for the project-specific application of the package or the accuracy and completeness of the documents filed with DOB. A deviation from the package must be clearly identified on the construction documents and supported by project-specific engineering.

Storage is treated separately. On a heavy duty shed that will carry stored materials or equipment, the professional must verify by project-specific structural analysis that the required live-load capacity, "including a minimum reserve capacity of 150 pounds per square foot," is kept after the storage load is counted. "No storage or placement is allowed on a shed designed as a light duty or extra light duty sidewalk shed."

Where the lighter sheds could be used

Subdivision (e) limits two classes. A light duty shed may only protect work performed at a height of less than 100 feet above the ground. An extra light duty shed may only be installed in connection with buildings fewer than seven stories tall, where the highest point of the work is less than 100 feet above ground, and only to protect pedestrians from "façade inspection, maintenance, repair or restoration work."

Inspections and the old way

The person who performs the installation inspection under Building Code section 3307.6.5.7, and the inspection after an adjustment or repair under section 3307.6.5.9, "must be a registered design professional." Sheds built to a package remain subject to the special inspection requirements, "including but not limited to those for welding, bolts, and steel fabrication." Only corrosion-resistant fasteners may be used. Subdivision (l) keeps the conventional route open: a shed that differs from the packages is allowed but must fully comply with section 3307.6 and cannot use the exemptions in subdivision (d)(3).

What the rule does not settle

The proposed text does not set a price, a fee, or a penalty, and the Mayor's Office of Operations certification says it provides no cure period because it "does not establish a violation, modification of a violation, or modification of the penalties associated with a violation." The notice does not estimate what a package shed costs compared with a conventional one. The rule page shows six online comments and, when we looked, no DOB response to them. DOB may change the text before it adopts a rule.

Bottom line.

Nothing here is in force. If DOB adopts it as proposed, a board whose building needs a shed could ask its engineer whether one of the six packages fits the sidewalk, and whether the lighter classes apply to a low-rise facade job. The engineer would still design for the site and answer for the filing. A board should also ask, before signing a shed contract, which route the engineer is using, because the conventional design stays available.

Primary sources: DOB proposed rule notice and text (DOB-219 / 2026 RG 060); NYC Rules page for Sidewalk Shed Designs.